Airless pre-pressurized spray lubrication with one pump per nozzle, so every nozzle is set on its own: top and bottom of the strip, or right in the die. The lube is sprayed without mixing in air, so it sticks to the strip and leaves almost no mist. Refill the tank while the line runs.
Choose the reservoir (2 to 30 gal, or tankless) and the number of pumps (2 to 14). Magnetic-base or in-die bracket nozzles, a low-level float that stops the press and a keypad controller with 4 spray modes come with every system.
Control and options. Membrane keypad with hand-cycle button and low-level light. Cycles on a dry contact from the press or feeder, in Simple, Counter, Timer or Multi-spray mode. Options: in-die bracket nozzles (1 to 10 in), flextube and piston nozzles, air agitation for water-soluble lubes, automatic refill, level gauge, spray-line pressure sensors (24 VDC PNP, M12), magnetic-base limit switch, reservoir strainers and spray cabinets (8 to 72 in).
See full specifications ↓ Contact us for a quote → All oiling systems →
Choose options


| Model | 2-2 | 5-6 | 15-6 | 15-10 | 30-6 | 30-10 | 30-14 |
|---|---|---|---|---|---|---|---|
| Pumps / nozzles | 1 to 2 | 1 to 6 | 1 to 6 | 1 to 10 | 1 to 6 | 1 to 10 | 1 to 14 |
| Reservoir | 2 gal7.5 L | 5 gal19 L | 15 gal57 L | 30 gal113 L | |||
| Size W × D × H | 14.5 × 11 × 14 in37 × 28 × 36 cm | 17.5 × 14 × 28.5 in45 × 36 × 72 cm | 21 × 17 × 42 in53 × 43 × 107 cm | 25 × 22 × 42 in63.5 × 56 × 107 cm | |||
| Approx. weight | 24 lb11 kg | 50 lb23 kg | 80 lb36 kg | 105 lb max.48 kg | |||
| Lube per cycle, std. | 0.021 oz (0.62 mL) per cycle × number of pumps | ||||||
| Lube per cycle, high vol. | 0.042 oz (1.24 mL) per cycle × number of pumps | ||||||
| Max. cycles / min | 300 at full volume, faster with less spray | ||||||
| Air pressure | 30 to 125 psi (205 to 860 kPa) | ||||||
| Max. air use | 0.002 scfm per cycle × number of pumps | ||||||
| Voltage | 115 VAC 60 Hz standard, other voltages on request | ||||||
Fed from a drum or your central lube supply.
| Model | 2T | 6T | 10T | 14T |
|---|---|---|---|---|
| Pumps / nozzles | 1 to 2 | 1 to 6 | 1 to 10 | 1 to 14 |
| Supply | Drum pump with filter and low-level float, or your central lube supply | |||
Lubricate the top and bottom of the strip, or several tooling stations, from one unit.
The controller sets how much lubricant is applied, so you use only what the job needs.
Pre-pressurized reservoir sized to your run length, for long runs between refills, tied into your press or rollformer controls.